You must enable javascript in order to view this page or you can go
here
to view the webhelp.
Optima MR360/Brivo MR355 1.5T
Content
Search
Keywords:
Loading, please wait ...
Optima MR360 / Brivo MR355 1.5T Service Methods
Read me
Language Policy
Revision History
Glossary
Safety
Personal Protective Equipment
Emergency Magnet Rampdown
Lock Out/Tag Out
LOCKOUT TAGOUT Procedure and Checklist
OSHA Lockout Tagout Requirements
Lockout / Tagout for MDP (Main Disconnect Panel) or Facility PDU
Lockout / Tagout for System Cabinet PDU Main Breaker
Lockout / Tagout for the Simple OC
Magnetic Field Considerations
Cryogens Safety
Oxygen Monitor Safety
High Voltage Safety
RF Field Safety
System Startup and Shutdown
Phantom Content Solutions and Spill Procedure
MR Magnet - Safety Requirements
Arc Flash Safety
Pre-Installation
Pre-Installation
Installation
Brivo MR355 / Optima MR360 Mechanical Installation
Signa HDe to Optima MR360 System Upgrade Manual
Brivo MR355 to Optima MR360 System Upgrade Manual
System Option
ECG Leads Installation and Functional Checks
Option Software Installation
Signa Software Option Installation From eLicese
15336 Oxygen Monitor Subsystem
CADStream 4.1 Installation Manual
EC96 Oxygen Monitor
Magmon3 Installation and Service Manual
Adjust/Cals
System Level Procedures
Echo Planar Test (EPT)
Grafidy3 Procedure
DQA Tool II
LVShim Procedures
Grounding and Leakage Current Checks
Line Voltage Checks
System Gain Calibration
Probe-P Calibration and SNR Tests
Gradient System
Echo Planar Test (EPT)
Grafidy3 Procedure
RF System
Body and Head Maximum Power Setup and Calibration
TR Dynamic Disable Calibration
Universal Power Monitor (UPM)
Universal Power Monitor - Body Setup and Calibration
Universal Power Monitor - Head Setup and Calibration
Magnet System And Enclosure
Dock Motor Gear Assembly Adjustment
Motor On Switch Actuation Adjustment
Oxygen Monitor Subsystem Manuals
Laser Light Alignment
LINUX PC-Global Operator Console
LCD Monitor Setting for NEC P242W Video Monitor
HP HC240 monitor calibration
Intercom Adjustment For Simple OC Audio Board
Configuring a Printer on Linux Systems (Generic Applications)
Light Weight Patient Table
Dual Table Alignment Procedure
Patient Transport Movement Verification
Hydraulic Fluid Level Check and Fill
Dock Pedal Stroke Adjustment
Cradle Release Pin Height Adjustment
Cradle Home Table Down Interlock Adjustment
Cradle Guide Rail Latch Adjustment
Cradle Release Block Adjustment
Table Top Height Adjustment
Dock Hook Tension Adjustment
Leveling Patient Transport
Removing Cradle Assembly
Longitudinal Drive Motor Alignment to Field
Longitudinal Drive Clutch Tension Adjustment
Longitudinal Drive Calibration
Longitudinal Drive Calibration Overview
Dock Centering and Dock Hardware Adjustments
Cradle Release Adjustment
Cradle Release from Carriage Adjustment
Cradle Release from Patient Transport Adjustment
Lite Patient Transport Service Methods
Dir 2377126 Lite Patient Transport Service Methods Manual
Fixed Table
Leveling Fixed Table
TOP HEIGHT ADJUSTMENT
CRADLE SLIDE LOCK ADJUSTMENT
CRADLE GUIDE RAIL LATCH ADJUSTMENT
CRADLE EMERGENCY RELEASE CHECK AND ADJUSTMENT
Power Distribution Unit
Optima MR360/ Brivo MR355 1.5T 25kVA PDU Module
MDP
Signa GE MDP
Surface and Head Coils
1.5T Coil Vendor Manuals for Signa Optima MR360/Brivo MR355
Blowers and Chillers
Coil Blower and Chiller Assemblies
Functional Cks
System Level Functional Checks
ECG Leads Checks
Emergency Stop and Off Check for Signa Brivo355/Optima360
Forward Reverse Quadrature Check
Full Field Distortion
Geometry Verification
PAC Manual Test
Peripheral Pulse Probe Check
Respiratory Compensation Checks
Signal To Noise Check
Spike Noise Check
Slice Thickness and Resolution
Slice Offset Checks
System Level Correlated Noise Check
PAC Leakage Current Test
DAQA Check
Environmental Checks
System Cabinet
Fiber Optic Checks
Fiber Optic Checks
Fiber Optic Light Meter Kit Parts Break Down.
STIF Board SRI PAC Fiber Optic Checks
Terminal Server Communications Diagnostic
XFA Gradient
RF Functional Checks
Simple RF Integrity Test
UPM- Body and Head Functional Check
Magnet Enclosure
Cradle Motion Test
Magnet Enclosure Button Test
Laser Light Alignment
Light Weight Patient Table
Patient Transport Movement Verification
Lite Patient Transport Service Methods
Dir 2377126 Lite Patient Transport Service Methods Manual
Fixed Table
CRADLE HOME SENSOR CHECK
TABLE CHECKS AFTER INSTALLATION
Power Distribution Unit
Optima MR360/ Brivo MR355 1.5T 25kVA PDU Module
MDP
Signa GE MDP
Surface and Head Coils
1.5T Coil Vendor Manuals for Signa Optima MR360/Brivo MR355
Multi-Coil Quality Assurance (MCQA) Tool
Blower and Chillers
Coil Blower and Chiller Assemblies
Coolant Check of MCS and 8kw or 4kw LCS
Software
System Host Software
Loading Host System Software
Loading Host System Software (SV20.0 Later)
Re-Configuring The System
Installing Software Patches (General Guide)
Verifying Save Restore Media
System Level Software Utilities
CD and DVD Functions
Configuring a Printer on Linux Systems (Generic Applications)
Configuration File Manager
Determining the Software Revision for Linux
Determining GE Coil Type
Printer Configuration for Film Composer
Error Number Decoder
Error Log Utility
File Editors
hinv Command
Image Extraction
Installing Service Methods CD Onto System
Installing Online Help CD/DVD Onto System
Product Network Filters
Hardware Status Check
Message Log
Raw File Manager
Stage and Custom Configurations
Service Licensing (SV20.0 Later)
Sprsnap Tool
SPR SNAP (SV20.0 Later)
System Startup and Shutdown
SPT Stability Viewer
System Health Check
T File Cleanup
Verifying Save Restore Media
Auto Voice Language Selection
E-Reporting Tool
CAM IP change procedure
Theory
System Theory
CAM Lite2 Theory
Coil ID Theory for Brivo MR355/Optima MR360
Cabinet Monitor Design Specification
Cooling System Diagram for System Cabinet
Leak Sensor Location and Function
Optima MR360/ Brivo MR355 1.5T 25kVA PDU Module
Gradient Theory
Working With Grafidy 3
XFD
RF Subsystem
Receive Chain Theory
Sys Diagrams
Signa Optima MR360/Brivo MR355 System Block Diagram
Cooling System Diagram for System Cabinet
Planned Maintenance
Planned Maintenance (PM) Schedule Overview
E-Reporting Tool
Schedule 1 Warranty Planned Maintenance
Schedule 2 Warranty Planned Maintenance
Include all Schedule (A) Planned Maintenance
Include all Schedule (B) Planned Maintenance
Include all Schedule (C) Planned Maintenance
Include all Schedule (D) Planned Maintenance
IBIS Specifications - Optima MR360/Brivo MR355
Lite Patient Transport PM
Dir2387327 Periodic Maintenance
Troubleshooting
Diagnostics
Running Overnight Diagnostics
System Function
Acquisition/Pulse Generation
Data Acquisition
TRF BLD
IRF3 BLD
IRF3 BLD
AGP and SCP Board Level Diag
AGP
SCP
IRF3 Fiber Loopback Diagnostic
IRF3 Wide Coverage Diagnostic
DVMR Link Status Diagnostic
Global Operator Console
Host Datapath Diagnostics
Keyboard Diagnostics
Keyboard Datapath
Keyboard Loop Test
Keyboard Audio Test
Keyboard SCP Loop Test
Keyboard STIF Loop Test
Terminal Server Communications Diagnostic
Terminal Server Loopback Diagnostic
Gradient
Grad Hammer
Grad Framing Error / Clock Stop Test
Grad ECC Verification
Grad Hysteresis Test
Patient Handling
SRI Functional Diagnostics
Magnet Enclosure Display Test
Magnet Enclosure Button Test
SRI Fiber Optic Transmitter Test
SRI Loop Test
SRI Motion Test Help
STIF-SRI Fiber Optic
SRI XRam Test
SRI Coil Id - Mega Switch
SRI Coil ID Stress Test
SRI Datapaths
SRI PWM Test
SRI Ram Test
SRI Enc. (Encoder) Test
SRI SCP Loop Test
SRI STIF Loop Test
SRI Register
SRI EEPROM Test
SRI STIF/PSE Loop Test
SRI SCP Loop Test (SV20.0 Later)
PHPS Function Diagnstics
I/O Status
Download Amp Config
Upload Amp Config
Reset Amp Motor
Amp Realtime Data
Download new code to servo amp
CAN Link Diagnostic
Peripheral Communications
CAN Link Diagnostic
Host Datapath Diagnostics
IRF3 Wide Coverage Diagnostic
Fiber Optic Diagnostics
Cabinet Monitor Functional Check
1-Wire Network Diagnostic
Recon
VRE Communication Diagnostics
Doing host-ICN Ethernet path diagnostics
Host- ICN Ethernet Stress
Host- ICN IPMI Path
Host- ICN Remote Shell
VRE Hardware Diagnostics
ICN CPU Stress
ICN Memory Stress
ICN Hard Disk Health
ICN Hard Disk Stress
ICN Hard Disk Integrity
VRE Reconstruction Diagnostics
VRE Sensors Display
VRF Communication Diagnostics
ICN VRF -> ICN Fast Feedback Path
ICN RRX -> VRF Datapath
VRF Hardware Diagnostics
VRF Manual Diagnostics
ICN VRF Manual Loopback Diagnostics
VRF Status Display
VRF Status Display
RF
Receiver Board Diagnostics
RRX Board Level Diagnostics
TNS DP
SRF to RRX+DTX DP
RF Calibration DP
DTX to RRX DP
Transmitter Diagnostics
DTX BLD
RF Calibration DP
DTX to RRX DP
IRF3 Fiber Loopback Diagnostic
Unblanking Functional Diagnostic
UPM Diagnostics
I/O Data
Analog Data
Driver Module Diagnostics
Power Supply Data
I/O status
Gather Load Data Diagnostic
RF Amp Diagnostics
RF Amplifier Diagnostics
RF Amplifier Diagnostics - PSU Voltage Test
RF Amplifier Diagnostics - Quick Diag
Hardware Location
Global Operator Console
Host Datapath Diagnostics
Keyboard Datapath
Keyboard Loop Test
Keyboard Audio Test
Keyboard SCP Loop Test
Keyboard STIF Loop Test
Terminal Server Communications Diagnostic
Terminal Server Loopback Diagnostic
Magnet Room
Receiver Diagnostics
RRX Board Level Diagnostics
TNS DP
RF Calibration DP
DTX to RRX DP
SRF to RRX+DTX DP (SV20.0 Later)
PAC Diagnostics
SRI Diagnositics
SRI Datapaths
SRI SCP Loop Test (SV20.0 Later)
SRI STIF/PSE Loop Test
System Cabinet
Transmitter Diagnostics
DTX BLD
RF Calibration DP
DTX to RRX DP
PHPS Functional Diagnostics
I/O Status
Download Amp Config
Upload Amp Config
Reset Amp Motor
Amp Realtime Data
Download new code to servo amp
Driver Module Diagnostics
Power Supply Data
I/O status
Gather Load Data Diagnostic
CAM
Data Acquisition
TRF BLD
IRF3 BLD
IRF3 BLD
AGP and SCP Board Level Diagnostics
AGP
SCP
UPM Diagnostics
I/O Data
Recon
VRE Communication Diagnostics
Doing host-ICN Ethernet path diagnostics
Host- ICN Ethernet Stress
Host- ICN IPMI Path
VRE Hardware Diagnostics
ICN CPU Stress
ICN Memory Stress
ICN Hard Disk Health
VRE Sensors Display
VRF Communication Diagnostics
ICN VRF -> ICN Fast Feedback Path
ICN RRX -> VRF Datapath
VRF Hardware Diagnostics
VRF Manual Diagnostics
ICN VRF Manual Loopback Diagnostics
VRF Status Display
RF
Unblanking Functional Diagnostic
RF AMP Diagnostics
RF Amplifier Diagnostics
RF Amplifier Diagnostics - PSU Voltage Test
RF Amplifier Diagnostics - Quick Diag
IRF3 Fiber Loopback Diagnostic
Gradient
Help Documentation
VRE Help Page
CAM Lite2 Theory
CAN Link Help Pages
Misc
Troubleshooting Steering Guide
Water Leak Troubleshooting
Leak Sensor Location and Function
CAM Lite2 ASC Part Theory and Troubleshooting
PHPS Lite Functional Check
PACS System Verification And Troubleshooting
MegaSW3 Troubleshooting
HIS/RIS Setup and Troubleshooting
HNU Troubleshooting
Cryocooler Troubleshooting
MR Front Status Indicator Troubleshooting Guide
RF Subsystem
SRFD3 Troubleshooting Flow Chart
XFD Gradient Troubleshooting
Monitoring DC Offsets for the XFD
XFD-PS LEDs
XFD Power-Up Diagnostics
Monitoring DC Offsets for the XFD
PDU
Optima MR360/ Brivo MR355 1.5T 25kVA PDU Module
EXCITE System Cabinet
hinv Command
Troubleshooting the Term Server
Patient Table
Lite Table Troubleshooting Guide
Fixed Table Troubleshooting Guide
Image Quality Troubleshooting Tools
SPT Stability Viewer
Multi-Coil Quality Assurance (MCQA) Tool
Parts
Illustrated Parts
Replacement
Operator WorkSpace Replacement
Computer Replacement
Hard Disk Drive Replacement
HUB Replacement
Simple OC Power Distribution Supply Replacement
PCI AA Replacement
Replacing/Installing the SCIM, Keyboard and Mouse
NEC LCD 2490WUXi2 Replacement
LCD Monitor Replace with HP HC240
DIMM memory Replacement
DVD Drive Replacement
Clean Dust Filter / Dust Filter Replacement
Host PC CPU Fan
System Cabinet Replacement
CAM Lite
CAM Lite 2 Front Boards
CAM Lite 2 Rear Boards
CAM Lite 2
CAM Lite 2 Fan Assy
PS for each module
PS for PHPS Lite 2
PS for LED Power Box
PS for Driver Module Lite
PS for Exciter
PS for Mega SW and RRx
PS for PHPS Lite 2
PS for LED Power Box
PS for Driver Module Lite
PS for Exciter
PS for Mega SW and RRx
XFA and XFD-PS Replacement
XFA
Control Board for XFA
XFD-PS
Control Board for XFD-PS
PDU
PDU breaker 1 pole kit, 2 pole kit and 3 pole kit
Main Breaker
PDU Control Board
PDU EMI Filter
Contactor for Emegency Off
Contactor for Night Mode
Leak Sensor
Leak Sensor 2 (Front)
Leak Sensor 2 (Bottom)
Leak Sensor 2 (Tray1)
Leak Sensor 3 (Tray2)
Cabinet Rear Panel
Cabinet Interface Board
DM Filter
Exciter Connector Assy
Filter Panel Assy
RF Connector Assy
XFD Power Panel Assy
Gradient Filter
ICN Replacement
Water Manifold
HUB Replacement in System Cabinet
SRFD3
GP3
Driver Module Lite
Cabinet Monitor
Exciter
PHPS Lite 2
Top FAN Assy
Magnet Enclosure
Magnet Enclosure Table of Contents
Magnet Enclosure Control Panels
Laser Light Replacement
LCC Dock Replacement
Replacement of SRI (Scan Room Interface)
Front Bridge Assembly
Magnet Enclosure Control Panels
Temperature Sensor Replacement
Replacing Speaker
Replacement of PAC
Remote PAC Assy
Regulator Box
8ch Mega Switch for 1.5T
8ch RRx
Gear Belt
Rear Pedestal Removal
Rear Pedestal Removal
Patient Communication Box
LED Power Box Assy
Motor Drive Assy
Encoder Box
Encoder Assy
1.5T Body T/R SW & Hybrid
LED Power Box Assy
Bore Light Replacement
Rear Pedestal Sensor Flag Replacement
Dummy Load
Longitudinal Drive Motor and Gear Box Replacement
LPCA Replacement
MC Pre-Amp Assy Replacement
LPCA Assembly without cover
Cable and Track Assy Replacement
Bridge Plate Replacement
MIC with cable Replacement
MC Box Assy Replacement
MC Box Chassis Replacement
A Port Coil Connector Replacement
LPCA Cover Removal
Coil Replacements
RF Shield Replacement
Dynamic Disable Switch
Removing Dynamic Disable Switch Board
Installing Dynamic Disable Switch Board
BRM/CRM RF Body Coil Replacement Procedure
Replacing BRM-D (Short) RF Body Coil
Gradient Coil Replacement
Defective Gradient Coil Removal
Gradient Coil Replacement Preparation
Gradient Coil Installation Procedure
Returning Plates to Gradient Insertion Tool Kit
1.5T Coil Vendor Manuals for Signa Optima MR360/Brivo MR355
Light Weight Patient Table
Patient Transport Component Replacement
Patient Transport Side Cover Removal
Cradle Assembly Removal
Patient Table Hydraulic Cylinder
Patient Table Hydraulic Pump Assembly
Patient Table Casters
Dock Hook
Table Up Limit Cable
Secondary Cradle Latch Actuating Cable
Cradle Interlock Cable
Main Cradle Latch Cable
Hydraulic Filter Replacement
Bleeding Patient Transport Hydraulics
Signa Table Arm Board Bumper Field Repair/Replacement Procedure
Lite Patient Transport Replacement
Dir 2377126 Lite Patient Transport Service Methods Manual
Fix Table
Cradle Home Sensor
TABLE ELECTRICAL ACTUATOR
TABLE CONTROL BOARD CABLES
TABLE ACTUATOR CABLE
PA COIL COAXIAL AND DC CABLE
TABLE TOP ASSEMBLY
Delrin wheel Replacement
FOOT SWITCH AND FOOT PEDAL CABLE
TABLE TOP FOOT END BUMPER
TABLE TOP HEAD END BUMPER
TABLE TOP SIDE BUMPER
Express Coil: Posterior Array Coil Replacement with removing Fixed Table
Express Coil: Posterior Array Coil Replacement without removing Fixed Table
UP LS Actuator
Convert Board 3
Table Control Box
Express Coil except PA Coil
Express Coil: Anterior Array Cable Replacement
Express Coil: Head Neck Array Coil Cable Replacement
Express Coil: Head Neck Array Mirror Repair/Replacement
Express Coil: Head Neck Array Coil Latch Replacement
Express Coil: Head Neck Array Coil ID PCB Replacement
Coil Blower and Chiller Assemblies
MCS Replacement
MCS Circuit Breaker Replacement
8kW LCS Replacement
4kW LCS Replacement
4KW LCS Low Level FRU Replacement
Coil Blower and Chiller Assemblies
Blower Box Motor Replacement
MDP
MDP Battery and Charger Kit Replacements
Your browser does not support iframes.